Home > News > Company News > Properly Installation of Home Alarm System Detectors
News
Industry News
Company News
Certifications
Latest News

The difference between the scope and application of UPS and EPS power

The difference between the scope and application of UPS and EPS power UPS working principle and classification UPS working principle is to use the...

What is an infrared sensor

What is an infrared sensor Infrared sensing system is used for the infrared measurement system for the medium, according to the function can be divi...

How the Magnetic contact sensor works

How the Magnetic contact sensor works? Magnetic contacts are the most common sensing devices for sensing opening and closing of doors and windows. The...

Active infrared and passive infrared alarm features, differences and application

Active infrared and passive infrared alarm features, differences and application Works for the infrared emission of infrared emission tube infrared...

Security in the GSM system

Security in the GSM system As a result of recent mainstream controversy involving David Beckham’s alleged text messages, some articles have been publ...

Emergency resettable alarm button

Emergency resettable alarm button       Emergency resettable alarm button,it can be installed in the fire hydrant box as...

How to choose Standalone control Keypad

  Quality and performance advantages anddisadvantages of Standalone Access control keypaddirectly affects the stability of the accesscontrol system,...

How to buy a home burglar alarm products

[Abstract] home burglar alarm product is the use of various types of peripheralfunctions detectors, space, environment and people's overall housing te...

SMQT's Access Control Products Passed ISO Certification

SMQT's Access Control Products Passed ISO Certification On March 27th, 2018, SMQT passed the strict inspection, test and evaluation of the company...

How to install the access control system?

     How to install the access control system? There are a number of responsibilities which come with the owning and operating of a business. Wit...
Contact Us
Address:Room 211, 2nd Floor, Zhongzhi NEXone,  Qingquan Road and, Longhua District, Shenzhen, China
Postal Code: 518109
Phone: 86-755-82838361 / 62/63
Email: sales@eiseis.com
       sales@2eiseis.com<
Contact Now
Share

Properly Installation of Home Alarm System Detectors

Properly Installation of Home Alarm System Detectors

Snoppy Huang CPS network Forum 2016-07-01 15:10:25
Properly Installation of Home Alarm System Detectors
Wirless Magnetic door detector installation requirements:

    1. door detectors installed on your need for surveillance of the door or window frame, that Menci detectors (main member, deputy member) fixed to the door frame.
    2. the false alarm rate and the location of the installation have a great relationship, the recommended installation location should be the main member and the deputy member gap ≤2mm.
 
Wireless infrared detector installation:

    1. infrared probe can only be installed in the room, its false alarm rate and the location of the installation have a great relationship, correct position from the ground should be 2.0 - 2.2 m; away from air conditioners, refrigerators, stoves and other areas sensitive to changes in air temperature.

    2. infrared probe should be installed in the corner of the room to get the best detection range, without Partition, furniture, large bonsai or other partition within the detection range.
    3. indoor infrared probe should be walking the line was a certain angle, infrared sensor for the radial movement of the reaction is not the most sensitive, and for tangential (ie, perpendicular to the radius direction) to move the most sensitive. In the field to select the appropriate installation position to avoid false positives infrared sensor, and seek the best detection sensitivity is extremely important part.
Wireless gas detector installation requirements:

    1.the installation:
    a) First, determine the proportion of combustible gas and air, and then the alarm is fixedly mounted in a suitable location away from the gas source 1.5M within a radius of: A Gas: lighter than air, floating aloft; B Gas: lighter than air, floating aloft; C LPG: heavier than air, accumulate in low;
    b) After the power is turned on, the alarm "beep" and the power light lit, functional light flashes green, about 2 minutes later extinguished, that has entered the alert, sensing when a gas leak, that issued a "tick , beep "alarm sound, while the function light is flashing red, alarm automatically alert the exclusion;
    c) if the sensor fails, the alarm is issued "Di -" long song, features a long bright yellow lights, troubleshooting, automatic alert.
    2. Notes:
    a) Do not install outdoors;
    b) Do not install to the air intake, fan, door, etc. where a large wind flow;
    c) Do not install beyond the 10 ~ 50 ℃, or more humid places;
    d) Do not install the alarm object and gas equipment isolated place;
    e) Avoid extensive use of solid hair spray, pesticides, paint, adhesive, diluted alcohol near the alarm;
    f) if the alarm failure, do not disassemble repair yourself, you can notify the supplier, or the nearest agency process. 

 Wireless smoke detector installation requirements: 
 
   1.the installation:
   Choose a good monitoring area, the alarm is mounted on the fixed surveillance area Jin roof or ceiling can be.
    2.Notes:
    a) Do not install outdoors;
    b) Do not install to the air intake, fan, door, etc. where a large wind flow;
    c) Do not install beyond the 10 ~ 50 ℃, or more humid places;
    d) alarm installation location away from the corner must be greater than 0.75 m;
    e) must be dust and moisture;
    3. Maintenance:
    a) due to dust and other factors will cause alarm sensitivity loss, it must be tested frequently and maintenance:
    b) once a week detector alarm, press the test button;
    c) cleaning every six months once the alarm: Turn off the power, with a soft brush to clean the dust.