Bahay > Balita > News Industry > RS-422 to RS-485 converter
Balita
News Industry
News Company
Certifications.
Pinakabagong Balita

Ang pagkakaiba sa pagitan ng mga saklaw at aplikasyon ng UPS at EPS kapangyarihan

Ang pagkakaiba sa pagitan ng mga saklaw at aplikasyon ng UPS at EPS kapangyarihan UPS nagtatrabaho prinsipyo at pag-uuri UPS nagtatrabaho prinsipy...

Ano ang isang infrared sensor

Ano ang isang infrared sensor Infrared sensing system ay ginagamit para sa infrared na sistema ng pagsukat para sa medium, ayon sa mga pag-andar ay ...

Paano ang Magnetic contact sensor gawa

Paano ang Magnetic contact sensor gawa? Magnetic contact ay ang pinaka-karaniwang sensing aparato para sensing pagbubukas at pagsasara ng mga pinto at...

Active infrared at passive infrared tampok alarma, mga pagkakaiba at application

Active infrared at passive infrared tampok alarma, mga pagkakaiba at application Gumagana para sa infrared emission ng infrared emission tube infra...

Security in the GSM system

Security in the GSM system As a result of recent mainstream controversy involving David Beckham’s alleged text messages, some articles have been publ...

Emergency resettable alarm button

Emergency resettable alarm button       Emergency na resettable alarma na pindutan,maaari itong i-install sa fire hydran...

Kung paano pumili ng Standalone control Keypad

  Kalidad at pagganap ng pakinabang atdisadvantages ng Standalone Access control keypaddirectly nakakaapekto sa katatagan ng accesscontrol system, a...

Paano upang bumili ng bahay magnanakaw alarma produkto

[Abstract] bahay magnanakaw alarma produkto ay ang paggamit ng iba't-ibang uri ng paligidfunction detectors, space, kapaligiran at mga tao ang pangkal...

Ang Mga Produkto ng Kontrol sa Pag-access ng SMQT ay Lumipat sa ISO Certification

Ang Mga Produkto ng Kontrol sa Pag-access ng SMQT ay Lumipat sa ISO Certification Noong Marso 27, 2018, pumasa ang SMQT sa mahigpit na inspeksyon,...

Paano mag-install ng access control system?

Paano mag-install ng access control system? Mayroong isang bilang ng mga responsibilidad na nanggaling sa mga aari at operating ng isang negosyo. Sa l...
Makipag-ugnayan sa amin
Address:Room 211, 2nd Floor, Zhongzhi NEXone,  Qingquan Road at, Longhua District, Shenzhen, China
Postal Code: 518109
Telepono: 86-755-82838361 / 62/63
Email: sales@eiseis.com
sales@2eiseis.com<
Makipag-ugnay ngayon
Ibahagi

RS-422 to RS-485 converter

RS-422 to RS-485 converter

Helen Li SMQT 2016-06-03 17:11:24
RS-422 to RS-485 converter 





Data Transmission Signals   

Unbalanced Line Drivers   

Each signal that transmits in an RS-232 unbalanced data transmission system appears on the interface connector as a voltage with reference to a signal ground. For example, the transmitted data (TD) from a DTE device appears on pin 2 with respect to pin 7 (signal ground) on a DB-25 connector. This voltage will be negative if the line is idle and alternate between that negative level and a positive level when data is sent with a magnitude of ±5 to ±15 volts. The RS-232 receiver typically operates within the voltage range of +3 to +12 and -3 to -12 volts as shown in Figure 1.1.




Balanced Line Drivers  

In a balanced differential system the voltage produced by the driver appears across a pair of signal lines that transmit only one signal. Figure 1.2 shows a schematic symbol for a balanced line driver and the voltages that exist. A balanced line driver will produce a voltage from 2 to 6 volts across its A and B output terminals and will have a signal ground (C) connection. Although proper connection to the signal ground is important, it isn't used by a balanced line receiver in determining the logic state of the data line. A balanced line driver can also have an input signal called an “Enable” signal. The purpose of this signal is to connect the driver to its output terminals, A and B. If the “Enable” signal is OFF, one can consider the driver as disconnected from the transmission line. An RS-485 driver must have the “Enable” control signal. An RS-422 driver may have this signal, but it is not always required. The disconnected or "disabled" condition of the line driver usually is referred to as the “tristate1” condition of the driver. 1 The term “tristate” comes from the fact that there is a third output state of an RS-485 driver, in addition to the output states of “1” and “0.”