Security products are now microelectronic products, especially security monitoring devices, these products have a high density, high speed, low voltage and low power consumption. Therefore, these products are very sensitive to IP protection class requirements are relatively high, if these parameters oversight standards, will affect operation of the entire security system or security products. IP represents Ingress Protection (ingress protection), protection class IP system provides a method for electrical equipment and packaging dustproof, waterproof and anti-collision extent to which the product classification.
When we conduct security equipment selection, we must first determine that the product is suitable for indoor or outdoor, and then based on the introduction of security products provider to select a product, so it is important parameters on the product, the product will be on some parameters indicate the degree of protection standards, we are determined to this standard. Protection class that contains the two concepts, one is dustproof, the other is the water level.
IPAB wherein A represents a dustproof, B represents the water level, generally based on figures to represent the meaning of such a product. For example, a camera specification protection class IP67, indicates that the product can completely prevent dust entering and prevents flooding of water intrusion.
Test security products IP rating Standard Specification
(1) IPA 1 Method Name: Vertical dripping test
Test Equipment: dripping test device
Sample placement: normal operating position by placing the sample in order to 1r / min rotation sample stage, sample top to drip from the mouth of not more than 200mm.
Test conditions: dripping capacity of 10.5 mm / min Duration: 10 min
(2) IPA 2 Method name: Tilt 15 ° drip test
IPAB wherein A represents a dustproof, B represents the water level, generally based on figures to represent the meaning of such a product. For example, a camera specification protection class IP67, indicates that the product can completely prevent dust entering and prevents flooding of water intrusion.
Test security products IP rating Standard Specification
(1) IPA 1 Method Name: Vertical dripping test
Test Equipment: dripping test device
Sample placement: normal operating position by placing the sample in order to 1r / min rotation sample stage, sample top to drip from the mouth of not more than 200mm.
Test conditions: dripping capacity of 10.5 mm / min Duration: 10 min
(2) IPA 2 Method name: Tilt 15 ° drip test
Test Equipment: dripping test device
Place the sample: the sample surface and perpendicular to a 15 ° angle, the sample top to drip from the mouth of not more than 200mm. After each test a finished surface, from another side, a total of four times.
Test conditions: dripping capacity of 30.5 mm / min Duration: 4 × 2.5 min (total 10 min)
(3) IPA 3 Method name: water spray test
a, test equipment: swing tube splashing water spray test device
Sample placed: Select the appropriate radius of the swing tube, put the sample surface height in the tube diameter position, the sample was placed on the sample stage to the top of the spout to sample distance of not more than 200mm, not rotating sample stage.
Test conditions: water flow by water holes put tubes is calculated, each hole is 0.07 L / min, when watering, swing pipe water spray holes on each side of the midpoint within a 60 ° arc sprayed samples. Test samples were placed in the center of swing pipe semicircle. Swing pipe along the vertical sides of the swing 60 °, a total of 120 °. Each swing (2 × 120 °) about 4s
Test time: 10 min continuous water spray
b, Test equipment: hand-held water spray splash test device
Sample placement: to make the top of the test at between 300mm to 500mm handheld nozzle spout of parallel distance
Test conditions: Test should be installed with the baffle balance weight, the water flow rate of 10 L / min
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area), at least 5 min.
(4) IPA 4 Method name: splash water test
a, swing tube splashing water test
Test equipment and sample placement: IPX a paragraph 3 above are the same;
Test conditions: In addition to the conditions described below, the IPX a paragraph 3 above are the same; water area of water pipe midpoint of each side of the swing arc of 90 ° in paragraph blowholes sprayed samples. Test samples were placed in the center of swing pipe semicircle. Swing pipe along the vertical sides of the swing 180 °, a total of about 360 °. Each swing (2 × 360 °) about 12s
Test time: above IPX 3 of a paragraph are the same (ie, 10 min).
b, sprinklers splashing water test
Test equipment and sample placement: IPX b paragraph 3 above are the same;
Test conditions: Install the bezel with the balance weight on the device removed, the rest of the above IPX b of paragraph 3 are the same;
Test Time: IPX b paragraph 3 of the above are the same, ie sample shell surface areas, per square meter of 1 min (not including installation area) at least 5min
(5) IPA 5 Method name: water spray test
Test equipment: nozzle spout diameter of 6.3mm
Test conditions: test samples to make the mouth water apart 2.5m ~ 3m, water flow rate of 12.5 L / min (750 L / h)
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area) at least 3 min
(6) IPA 6 Method Name: strong water spray test
Test equipment: spray nozzle mouth diameter of 12.5 mm
Test conditions: test samples to make the mouth water apart 2.5m ~ 3m, water flow rate of 100 L / min (6000 L / h)
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area) at least 3 min
(7) IPA 7 Method Name: short-term immersion test
Test equipment and test conditions: water immersion tank. The sample size should be placed in the box after flooding from the bottom of the sample to the surface of at least 1m. Top of the sample to the surface distance of at least 0.15m
Test time: 30 min
(8) IPA 8 Method Name: Continuous diving test;
Test equipment, test conditions and test time: from the supply and demand (sale) The two sides agreed that its severities should be higher than 7 IPX.
Place the sample: the sample surface and perpendicular to a 15 ° angle, the sample top to drip from the mouth of not more than 200mm. After each test a finished surface, from another side, a total of four times.
Test conditions: dripping capacity of 30.5 mm / min Duration: 4 × 2.5 min (total 10 min)
(3) IPA 3 Method name: water spray test
a, test equipment: swing tube splashing water spray test device
Sample placed: Select the appropriate radius of the swing tube, put the sample surface height in the tube diameter position, the sample was placed on the sample stage to the top of the spout to sample distance of not more than 200mm, not rotating sample stage.
Test conditions: water flow by water holes put tubes is calculated, each hole is 0.07 L / min, when watering, swing pipe water spray holes on each side of the midpoint within a 60 ° arc sprayed samples. Test samples were placed in the center of swing pipe semicircle. Swing pipe along the vertical sides of the swing 60 °, a total of 120 °. Each swing (2 × 120 °) about 4s
Test time: 10 min continuous water spray
b, Test equipment: hand-held water spray splash test device
Sample placement: to make the top of the test at between 300mm to 500mm handheld nozzle spout of parallel distance
Test conditions: Test should be installed with the baffle balance weight, the water flow rate of 10 L / min
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area), at least 5 min.
(4) IPA 4 Method name: splash water test
a, swing tube splashing water test
Test equipment and sample placement: IPX a paragraph 3 above are the same;
Test conditions: In addition to the conditions described below, the IPX a paragraph 3 above are the same; water area of water pipe midpoint of each side of the swing arc of 90 ° in paragraph blowholes sprayed samples. Test samples were placed in the center of swing pipe semicircle. Swing pipe along the vertical sides of the swing 180 °, a total of about 360 °. Each swing (2 × 360 °) about 12s
Test time: above IPX 3 of a paragraph are the same (ie, 10 min).
b, sprinklers splashing water test
Test equipment and sample placement: IPX b paragraph 3 above are the same;
Test conditions: Install the bezel with the balance weight on the device removed, the rest of the above IPX b of paragraph 3 are the same;
Test Time: IPX b paragraph 3 of the above are the same, ie sample shell surface areas, per square meter of 1 min (not including installation area) at least 5min
(5) IPA 5 Method name: water spray test
Test equipment: nozzle spout diameter of 6.3mm
Test conditions: test samples to make the mouth water apart 2.5m ~ 3m, water flow rate of 12.5 L / min (750 L / h)
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area) at least 3 min
(6) IPA 6 Method Name: strong water spray test
Test equipment: spray nozzle mouth diameter of 12.5 mm
Test conditions: test samples to make the mouth water apart 2.5m ~ 3m, water flow rate of 100 L / min (6000 L / h)
Test time: According to sample shell surface areas, per square meter of 1 min (not including installation area) at least 3 min
(7) IPA 7 Method Name: short-term immersion test
Test equipment and test conditions: water immersion tank. The sample size should be placed in the box after flooding from the bottom of the sample to the surface of at least 1m. Top of the sample to the surface distance of at least 0.15m
Test time: 30 min
(8) IPA 8 Method Name: Continuous diving test;
Test equipment, test conditions and test time: from the supply and demand (sale) The two sides agreed that its severities should be higher than 7 IPX.